A1 Acoustic Rhinometer Clinical/Research | A1-C/R

$9,288.00

An Acoustic Rhinometer produces a high intensity, very short duration sound pulse in the sound tube and this is applied to one side of the nose. Whenever this pulse meets a change in cross sectional area, a reflection is produced, which returns to the sound tube and is picked up by a microphone.

Description

An Acoustic Rhinometer produces a high intensity, very short duration sound pulse in the sound tube and this is applied to one side of the nose. Whenever this pulse meets a change in cross sectional area, a reflection is produced, which returns to the sound tube and is picked up by a microphone. The outgoing and returning signals are processed by a PC to provide a plot of cross sectional area, as a function of distance, into the nose. Numerical information such as the area at certain distances into the nose, and volumes between certain points in the nose, are calculated and presented, which highlight and quantify the points of obstruction.

Applications include:

  • Surgical pre/post comparisons
  • Nasal symmetry assessment
  • Allergen challenge recording
  • Sleep studies
  • Quantifying changes due to Surgery, Decongestants or Medication

The A1 Clinical/Research version provides a patient database, software calibration, colour selection facility for screen and printout, patient record screen editing, adjustable scale setting, calculation of the first two minimum areas, the distance at which minimas were found, the volume between any three distances, and user defined printout headings. A starter pack of consumables is also supplied. The A1 Clinical/Research version also adds the following:

  • System performance checking/adjustment tools, such as an artificial nose is included
  • Data export facilities – calculated or raw data, for external processing
  • Capability of adding additional sound tubes for paediatric or small animal research
  • A batch test facility, which allows data runs to be repeated, and mean, standard deviation and coefficient of variance calculations to be displayed and printed. This “best clinical practice” facility helps ensure top grade measurement accuracy.
  • Can be linked to our NR6 Clinical/Research Rhinomanometer, to allow a complete nasal functional measurement and linked patient record system

Five pairs of medium and large anatomically conformed nosepieces, and fifteen sets of 8mm conical nosepieces are also supplied. Software is supplied on a USB flash drive.

 

Clinical Clinical Research
Distance Range – Standard Sound Tube 12cm 12cm
Distance Range – Optional Small Animal Sound Tube 5cm 5cm
Distance Range – Optional Child Sound Tube 10cm 10cm
Area Range – Standard Sound Tube 0.1–20cm² 0.1–20cm²
Area Range – Optional Small Animal Sound Tube 0.001–0.3cm² 0.001–0.3cm²
Area Range – Optional Child Sound Tube 0.01–5cm² 0.01–5cm²
Volume Accuracy – Distance 0–5cm 2% 2%
Volume Accuracy – 5cm End 5% 5%
Information Reported – Standard Software 2x min areas, 3x volumes 2x min areas, 3x volumes
Information Reported – Multiple Report NO YES – Volumes & Areas
Information Reported – Data Export Facility NO YES
Product Dimensions: 27 x 6 x 28cm 27 x 6 x 28cm
Product Weight ~2Kg  ~2Kg
CE Mark Class IIa IIa
Complies with SC* Recommendations YES YES
‘Best Practise’ Batch Facility NO YES
Electrical Safety BS EN 60601 BS EN 60601

 